Product Warning & Recall Notice - Item #90226

July 2014

Hornady Manufacturing Company is recalling one (1) lot of 9mm 135gr +P Hornady Critical Duty™ Ammunition, Item #90226. This lot was shipped between the dates of 6-5-14 and 7-16-14.

ITEM #90226, LOT #3141635

Hornady Manufacturing Company ballisticians have determined that some cartridges from Lot #3141635 may exhibit light or no powder charges. Use of this product may result in firearm damage and or personal injury.

DO NOT USE HORNADY CRITICAL DUTY 9MM 135GR. +P, LOT #3141635. The lot number can be found printed on the underside of the box label.

THIS NOTICE ONLY APPLIES TO LOT #3141635.

If you own this lot number or have any questions regarding this recall, please call 800-338-1242. Hornady Manufacturing Company will make all arrangements associated with this return and replacement of the product.

ANY OTHER LOT NUMBERS OR ITEM NUMBERS ARE NOT SUBJECT TO THIS RECALL AND REQUIRE NO ACTION. Thank you for your attention. We apologize for this inconvenience.